Optical Water Dissolved Oxygen Sensor For Aquaculture Fishing Pond

Basic Information
Place of Origin: China
Brand Name: Desun Uniwill
Certification: CE
Model Number: DS-380
Minimum Order Quantity: 0~100 pcs
Price: $280.00 - $400.00/ Piece
Packaging Details: Carton packaging
Delivery Time: 7~ 15 working days
Payment Terms: L/C, D/A, D/P, T/T
Supply Ability: 0~1000 pcs
Detail Information
Model: DS380 Principle: Fluorescence Analysis Method
Measuring Range: 0~20mg/L Response Time: 3 Seconds
Accuracy: 1% Protection Level: IP68
Installation: Submersible Temperature Sensor: NTC
Temperature Range: 0~50°C Temperature Accuracy: ±0.2°C
Output: Support RS-485, MODBUS Protocol Power Supply: DC 6~12V, Current <50mA
Size: Φ26*155 Mm Probe Cable Length: Default 5 M
Fluorescent Cap Life: 1 Year Maximum Working Pressure: 3bar
Housing Material: SS316/Titanium Alloy
High Light:

Fishing Pond Dissolved Oxygen Sensor

,

Submersible Optical Dissolved Oxygen Sensor

,

Aquaculture Dissolved Oxygen Probe


Product Description

Optical Water Dissolved Oxygen Sensor For Fishing Pond In Aquaculture And Water

 

The function of Fluorescence dissolved oxygen sensor is to measure the oxygen content in the water. The oxygen in the water will change with the pressure, temperature and salinity. The higher the pressure, the higher the dissolved oxygen, and the higher the temperature, the higher the salt. Generally, the oxygen in the water is air Infiltration into the water, it can also generate oxygen through the plants in the water, but many reasons in the water will consume oxygen, resulting in insufficient oxygen content in the water, so professional instruments are required to detect the dissolved oxygen content in the water.

 

 

Technical Specifications

 

Item Parameters
Model DS380
Principle Fluorescence analysis method
Measuring range 0~20mg/L or 0-200% saturation
Response time 3 sec
Accuracy 1%
Protection level IP68
Installation Submersible
Temperature sensor NTC
Temperature range 0~50°C
Temperature accuracy ±0.2°C
Output Support RS-485, MODBUS protocol
Power supply DC 6~12V, current <50mA
Size Φ26*155 mm
Probe cable length Default 5 m, customized 10m, 15 m and 30 m cable
Fluorescent cap life 1 year
Maximum working pressure 3bar
Housing material SS316/Titanium alloy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensor maintenance

 

1) Sensor outer surface:

 

Clean the outer surface of the sensor with tap water. If there is still debris left, wipe it with a soft cloth. For some stubborn dirt, add some household washing liquid to the tap water to clean it.

 

2) The outer surface of the fluorescent cap:

 

Remove the protective cover at the front end of the sensor, rinse the dirt on the sensor window with clean water, and finally cover the cover; if you need to wipe, use a soft cloth and carefully wipe the force direction.

 

 