logo
Send Message
products

RS485 Online Aquarium Dissolved Oxygen Test Meter Digital Optical DO Meter

Basic Information
Place of Origin: China
Brand Name: Desun Uniwill
Certification: CE
Model Number: DYS-1
Minimum Order Quantity: 1 pcs
Price: $280.00 - $400.00/ Piece
Packaging Details: Carton packaging
Delivery Time: 7~ 15 working days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 0~1000 pcs
Detail Information
DO Range: 0~20mg/L Or 0~200% DO Accuracy: 1%
Sensor Material: Stainless Steel/Titanium Temp. Range: 0~40℃
Temp. Accuracy: ±0.2℃ Measuring Distance: 3m~5m
Working Temperature: -20℃~50℃ Power: <0.5w
Signal Output: RS-485
High Light:

Aquarium Online Dissolved Oxygen Meter

,

Digital Optical Dissolved Oxygen Test Meter

,

RS485 Dissolved Oxygen Test Meter


Product Description

Digital Optical DO Metre Dissolved Oxygen Test Meter Online Dissolved Oxygen Meter Aquarium for sale

 

DYS-1 Portable Do Meter INTRODUCTION

 

Features:

■ Hand-Measured Water Meter with multiple parameters display: DO and temperature.

■ Signal output:RS-485

■Support manual salinity compensation, air pressure compensation and manual/auto calibration.

 

Digital Optical DO Metre Dissolved Oxygen Test Meter

 

Application:

-Excellent to use in fresh water aqua farm.

-Excellent to use in sea water aqua farm.

 

Method for measuring dissolved oxygen


Three methods are available for measuring dissolved oxygen concentration. Modern technology involves electrochemical or optical sensors.

 

1.Dissolved oxygen sensors are connected to instruments used for field sampling and laboratory applications or to data loggers, process monitors or transmitters for deployment measurements and process control.
2.Colorimetric methods provide a basic approximation of the dissolved oxygen concentration in a sample. There are two methods designed for high and low range dissolved oxygen concentrations. These methods are fast and inexpensive for basic projects, but are limited in range and error prone due to the possible presence of other redox agents in the water.
3.The traditional method is the Winkler titration method. While this method has been considered the most accurate and precise for many years, it is also prone to human error and more difficult to perform than other methods.

 

Model

DYS-1

DO Range

0~20mg/L or 0~200%

DO Accuracy

1%

Dissolved Oxygen Sensor Drift

<1%per year

Sensor Material

SS316 or Titanium alloy

Temp. Range

0~40℃

Temp. Accuracy

±0.2℃

Measuring Distance

3m~5m

Sensor Cleaning Cycle

According to water condition and measuring frequency

Working Temperature

-20℃~50℃

Material Supplied

3v~6v

Power

<0.5w

Signal Output

RS-485

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DAILY MAINTENANCE

 

This instrument uses a fluorescent dissolved oxygen probe. When cleaning the probe, please use a wet soft cloth or a sponge, gently wipe the fluorescent film on the front end. For some stubborn dirt, some household detergents can be added to the tap water for cleaning.

 

NOTE:

  • Don‘t scrape the fluorescent film with hard objects, otherwise scraping the fluorescent film will be discarded.

  • Maintenance frequency suggests arranging cleaning cycle according to water condition.

  • The fluorescent film should be replaced once every 2 to 3 years.

  • When not in use, please put the front end of the sensor in a protective shield.

 

Contact Details
Wang

Phone Number : +86 181 8242 9986

WhatsApp : +8618182429986