Product Name: | Blue Green Algae Sensor | Principle: | Fluorescence Method |
---|---|---|---|
Measure Range: | 0-270, 000 Cells/mL | Resolution: | 1 Cells/mL |
Detection Limit: | 300 Cells/mL | Housing Material: | SS316 |
Power Supply: | 5~12vdc,current <50mA (when Not Cleaned) | Output Signal: | RS485, MODBUS Protocol |
IP Grade: | IP68 | Deepest Depth: | Underwater 10 Meters |
High Light: | 50mA Blue Green Algae Sensor,Blue Green Algae Sensor Digital,water testing probe SS316 |
★ Digital sensor, RS-485 output, support MODBUS
★ With automatic cleaning brush to prevent contamination and eliminate air bubbles
★ Direct measurement, simpler than traditional manual counting method
★ Continuous online monitoring, real-time control of water quality dynamics
Product name | Blue-green Algae Sensor |
model | DS206 |
principle | Fluorescence method |
Range | 0-270, 000 cells/mL |
Detection limit | 300 cells/mL |
Resolution | 1 cells/mL |
Linearity | R2>0.99 |
temperature range | 0~ 50°C |
Protection level | Ip68 |
Sensor interface | Support RS-485, MODBUS protocol |
Installation | Input type, |
Power information | DC 5~12V, current <50mA |
size | Φ45*175.8mm |
Probe cable length | 10 meters (default), can be customized |
Housing material | SS316 |
Self-cleaning system | Have |
Online blue-green algae sensor with automatic cleaning brush can be automatically cleaned without frequent cleaning.
Maintenance task | Recommended maintenance frequency |
Calibrate the sensor (if required by the competent authority) | According to the maintenance schedule required by the competent authority |
Cable Definition
The power supply must be DC 5-12V +/-5%, current <50mA
4 wire AWG-24 or AWG-26 shielding wire. OD=5mm
1, red line - power supply (VCC)
2, white line - 485 data _B (485_B) 3, green line --- 485 data _A (485_A) 4, black line --- ground (GND)
5, bare line shielding layer
Our company assures first-hand buyers that there will not be any product defects caused by substandard materials or factory manufacturing within one year from shipment.
Because the sensor has an automatic cleaning brush and a motor, it belongs to a dynamic seal structure. After 18 months of continuous use, the dynamic sealing device needs to be returned to the factory. If the buyer does not return to the factory and the sensor enters the water or fails to work, all consequences caused by the buyer shall be borne by the buyer If a defect is found during the warranty period, it is promised to repair or replace the defective product, or return the payment in addition to the first shipping and related formalities. Any product repaired or replaced during the warranty period will only enjoy the remaining warranty period of the original product.
After receiving the customer's questions about product quality, our company will confirm whether the product needs to be repaired within two weeks; products that have not been